Using vibration-monitoring equipment with “spike energy,” gSE or other high-frequency detection technology saves those on limited budgets from having to buy additional specialized greasing equipment with monitoring ability.
Article originally published on Noria.com.
If you already use vibration-monitoring equipment with “spike energy,” gSE or other high-frequency detection technology, you can optimize the quantity of grease added to a bearing by running your monitoring equipment while adding grease. When the overall level of the signal drops suddenly and noticeably, grease has reached the bearing. Stop adding more. Using this approach saves those on limited budgets from having to buy additional specialized greasing equipment with monitoring ability.